Piston Cylinder Apparatus(Depths of the Earth)

TheQUICKpress is a small, easy to use device that generates very-highpressures athigh temperatures.  MECHANICS  Itis used forhot isostatic pressing, thermodynamic studies, electrical studies,new materialssyntheses that include the development of novel ceramics,high-Tcsuperconducting structures, amorphous phosphides and nitrides,andtechnologically important metal-hydrides, as well as many other topicsinmaterials engineering science.  SELECTEDAPPLICATIONS

Very-highpressure generating insturments of the QUICKpress type arereferred to aspiston-cylinder devices and have been in use since 1955. Earlymodels were massiveand difficult and expensive to manufacture and operate. Thedesign describedhere (first developed in 1977), underwent major modificationsin 1988 tofurther improve the apparatus.  SPECIFICATIONS Asa consequence, ease of operation increased, while expense of productionandoperation decreased. At present, very little operator training is requiredtodo high-pressure high temperature piston-cylinder experiments,  EXECUTINGEXPERIMENTS although a great deal of scientific experienceand creativity may be needed toformulate experimental programs and interpretresults.   CAPSULES

  

TEMPERATURECONTROL UNIT

Depthsof the Earth Company’s temperature control unit sets and monitorssampletemperature, furnace current and voltage, and cooling waterflow. Expressly designed for the QUICKpress, the temperature control unitwillcontrol any process equipment that utilizes AC output to power resistiveorinductive loads.

KEY FEATURES:

Auto or Manual Microprocessor-based interface sets and monitorstemperature.

High-current phase-angle fired thyristor controls heating rate, coolingrate, or set-point temperature.

Single Segment programmable ramp/soak with max rate: 100°C/minute and min.rate: 3°C/minute

Unlimited run-duration

Control Signal instant switching between thermocouple types R, S, C, J, E,T, L, N, B

Automatic shut-down at temperature over-range, voltage or current outputover-range, cooling water system failure, or power outage.  Mechanicalrelay prevents automatic start-up after any alarm condition is restored.

 

TECHNICAL SPECIFICATIONS:

Dimensions: 46cm wide x 31cm deep x 15cm high

Power Requirements: 210 VAC dedicated line,single phase, 30amps

50Hz or 60Hz operation compatible

Stability + 2°C, Resolution + 1°C

Non-volatile memory retains parameters withoutbattery backup

10-foot power cord, plug not included.